Skip to main content
Moov logo

Moov Icon
SILVER SAGE PRECISION SDMxy100
    Description
    Dark-field laser surface-defect monitor
    Configuration
    Detection method: Dark-field laser scatter PSL sensitivity: 0.152 µm (152 nm) Size classes: 0.15 / 0.2 / 0.3 / 0.5 / 1.0 / 3.0 / 5.0 µm+ Scan motion: XY stage; substrate moves under the objective Output: XY defect map and size-class histogram Data storage: Scan files recalled from database Edge exclusion: Configurable in millimeters Reticle / mask: Glass-side scanning with system modification Pellicle: Feasibility testing available Non-silicon substrates: Substrate-specific PSL calibration required for accurate size classification Controller: Integrated laptop and software Power: 115 VAC Vacuum: Facility supply required
    OEM Model Description
    The SDM-100xy is a dark-field laser surface defect monitor capable of scanning 150mm–200mm silicon wafers, reticles, photomasks, and glass substrates. Scanning the glass side of a reticle is within capability with minor modifications; pellicle scanning feasibility can be tested. All non-silicon materials require a specific calibration to ensure accurate defect size classification.
    Documents

    No documents

    verified-listing-icon

    Verified

    CATEGORY
    Metrology

    Last Verified: 3 days ago

    Key Item Details

    Condition:

    Used


    Operational Status:

    Unknown


    Product ID:

    153184


    Wafer Sizes:

    Unknown


    Vintage:

    Unknown


    Logistics Support
    Available
    Transaction Insured by Moov
    Available
    Refurbishment Services
    Available
    Similar Listings
    View All
    SILVER SAGE PRECISION SDMxy100

    SILVER SAGE PRECISION

    SDMxy100

    Metrology
    Vintage: 0Condition: Used
    Last Verified3 days ago

    SILVER SAGE PRECISION

    SDMxy100

    verified-listing-icon
    Verified
    CATEGORY
    Metrology
    Last Verified: 3 days ago
    listing-photo-41dd054dd88f44d89ca45374a5f74c65-https://media-moov-co.s3.us-west-1.amazonaws.com/user_media/listingPhoto/48518/41dd054dd88f44d89ca45374a5f74c65/3bdf48ee62fd4d48a9ba5765ea356f35_01integratedlaptopcontroller_mw.jpg
    listing-photo-41dd054dd88f44d89ca45374a5f74c65-https://media-moov-co.s3.us-west-1.amazonaws.com/user_media/listingPhoto/48518/41dd054dd88f44d89ca45374a5f74c65/9eee3f7f9be14cf191b9859e6f992139_03threequartercabinetlaptop_mw.jpg
    listing-photo-41dd054dd88f44d89ca45374a5f74c65-https://media-moov-co.s3.us-west-1.amazonaws.com/user_media/listingPhoto/48518/41dd054dd88f44d89ca45374a5f74c65/9b4f737833294a10be5401790895e9d9_04rearpanelexhaustio_mw.jpg
    listing-photo-41dd054dd88f44d89ca45374a5f74c65-https://media-moov-co.s3.us-west-1.amazonaws.com/user_media/listingPhoto/48518/41dd054dd88f44d89ca45374a5f74c65/4beaaa7fc8874492a8814ff9f5f72195_02frontloadwindowestop_mw.jpg
    Key Item Details

    Condition:

    Used


    Operational Status:

    Unknown


    Product ID:

    153184


    Wafer Sizes:

    Unknown


    Vintage:

    Unknown


    Logistics Support
    Available
    Transaction Insured by Moov
    Available
    Refurbishment Services
    Available
    Description
    Dark-field laser surface-defect monitor
    Configuration
    Detection method: Dark-field laser scatter PSL sensitivity: 0.152 µm (152 nm) Size classes: 0.15 / 0.2 / 0.3 / 0.5 / 1.0 / 3.0 / 5.0 µm+ Scan motion: XY stage; substrate moves under the objective Output: XY defect map and size-class histogram Data storage: Scan files recalled from database Edge exclusion: Configurable in millimeters Reticle / mask: Glass-side scanning with system modification Pellicle: Feasibility testing available Non-silicon substrates: Substrate-specific PSL calibration required for accurate size classification Controller: Integrated laptop and software Power: 115 VAC Vacuum: Facility supply required
    OEM Model Description
    The SDM-100xy is a dark-field laser surface defect monitor capable of scanning 150mm–200mm silicon wafers, reticles, photomasks, and glass substrates. Scanning the glass side of a reticle is within capability with minor modifications; pellicle scanning feasibility can be tested. All non-silicon materials require a specific calibration to ensure accurate defect size classification.
    Documents

    No documents

    Similar Listings
    View All
    SILVER SAGE PRECISION SDMxy100

    SILVER SAGE PRECISION

    SDMxy100

    MetrologyVintage: 0Condition: UsedLast Verified:3 days ago
    SILVER SAGE PRECISION SDMxy100

    SILVER SAGE PRECISION

    SDMxy100

    MetrologyVintage: 0Condition: NewLast Verified:3 days ago