
Description
Lot of (Qty 4) Transmission Electron Microscopes (TEM) / (Qty 1) Dual Beam FIB-SEMConfiguration
FEI Tecnai G2 F30 TWIN 300 kV field emission TEM point resolution 0.24 nm / line resolution 0.14 nm Gatan UltraScan 4000 UHS MP camera single-tilt, single-tilt tomography and double-tilt holders 5-axis motorised goniometer, typical tomography tilt up to ±70° water chiller diffusion and turbomolecular vacuum pumps FEI Tecnai T20 Sphera 200 kV TEM 80-200 kV beam voltage point resolution 0.27 nm / line resolution 0.144 nm depending on site conditions FEI Eagle 4k USB camera X / Y 2 mm, Z 750 µm, alpha tilt ±70° single-tilt specimen holder cryo box and low-dose system oil-free accelerator / column pumping FEI Tecnai G2 F20 FEG Known issues: No camera or detectors 200 kV Schottky thermal field emitter TEM 80-200 kV point resolution 0.27 nm / line resolution 0.144 nm / information limit 0.18 nm depending on site conditions cryo blades FEG tip 2021, HT tank 2022 X / Y 2 mm, Z 750 µm, alpha tilt ±80° Windows XP interface and remote-control scripting camera: None detectors: None PHILIPS Tecnai F20 Ultra twin Known issues: Gatan camera reportedly out of order G1 system single-tilt and double-tilt sample holders FEI STRATA DB237 FEG SEM / focused ion beam dual beam for TEM lamella preparation SED / CDEM / TLD / STEM detectors 50 × 50 mm flip stage with TEM grid holder Omniprobe 100 platinum deposition and XeF2 (IEE) vacuum in 10^-6 mbar range after 24 h pumpingOEM Model Description
None ProvidedDocuments
No documents
Similar Listings
View AllLOT
EQUIPMENT
CATEGORY
Support Equipment
Last Verified: 3 days ago
Key Item Details
Condition:
Used
Operational Status:
Unknown
Product ID:
155473
Wafer Sizes:
Unknown
Vintage:
Unknown
Logistics Support
Available
Transaction Insured by Moov
Available
Refurbishment Services
Available
Description
Lot of (Qty 4) Transmission Electron Microscopes (TEM) / (Qty 1) Dual Beam FIB-SEMConfiguration
FEI Tecnai G2 F30 TWIN 300 kV field emission TEM point resolution 0.24 nm / line resolution 0.14 nm Gatan UltraScan 4000 UHS MP camera single-tilt, single-tilt tomography and double-tilt holders 5-axis motorised goniometer, typical tomography tilt up to ±70° water chiller diffusion and turbomolecular vacuum pumps FEI Tecnai T20 Sphera 200 kV TEM 80-200 kV beam voltage point resolution 0.27 nm / line resolution 0.144 nm depending on site conditions FEI Eagle 4k USB camera X / Y 2 mm, Z 750 µm, alpha tilt ±70° single-tilt specimen holder cryo box and low-dose system oil-free accelerator / column pumping FEI Tecnai G2 F20 FEG Known issues: No camera or detectors 200 kV Schottky thermal field emitter TEM 80-200 kV point resolution 0.27 nm / line resolution 0.144 nm / information limit 0.18 nm depending on site conditions cryo blades FEG tip 2021, HT tank 2022 X / Y 2 mm, Z 750 µm, alpha tilt ±80° Windows XP interface and remote-control scripting camera: None detectors: None PHILIPS Tecnai F20 Ultra twin Known issues: Gatan camera reportedly out of order G1 system single-tilt and double-tilt sample holders FEI STRATA DB237 FEG SEM / focused ion beam dual beam for TEM lamella preparation SED / CDEM / TLD / STEM detectors 50 × 50 mm flip stage with TEM grid holder Omniprobe 100 platinum deposition and XeF2 (IEE) vacuum in 10^-6 mbar range after 24 h pumpingOEM Model Description
None ProvidedDocuments
No documents