Description
i-line stepperConfiguration
Software: MSCV ver 2.42C OCSV ver 2.42 TOOL ver 2.51A OpenVMS VAX V6.1 Optics: Variable NA, max NA 0.63 Max field size: 22 x 22 SHRINC type 3 illuminator: conventional, 1/2 annular TTLFC2 focus check PPD Chip leveling Reticle: 6" reticle, 6" reticle case Fixed reticle microscope Reticle barcode reader Wafer handling: Notch wafers Ring-type wafer chuck Pre-alignment 2 (8", N) with 6-hammer Wafer loader type 3 Wafer carrier tables: left and right In-line ready (left side) Alignment: FIA LSA HP 5517C laser Facilities: NEMA box, 2 lines for CVCF Rack on right side Body-OP rack cable: 3M Chamber: Asahi S19 (1997) Chamber temperature: 23.0°COEM Model Description
"This i-line stepper from Nikon is one of our most popular lithography systems. Resolution ≦ 350 nm, exposure light source i-line (365 nm wavelength), reduction ratio 1:5, exposure field 22mm square to 17.9 (H) × 25.2 (V) mm (6-inch reticle), 20.0 × 20.4 mm (5-inch reticle), alignment accuracy (EGA, |M| + 3σ) ≦ 55 nm. The NIKON NSR 2205 i12D is a Steppers and Scanners system. The NSR 2205 i12D can be used with 8” wafer sizes.Documents
No documents
Verified
CATEGORY
Steppers & Scanners
Last Verified: 3 days ago
Key Item Details
Condition:
Used
Operational Status:
Unknown
Product ID:
162944
Wafer Sizes:
8"/200mm
Vintage:
Unknown
Logistics Support
Available
Transaction Insured by Moov
Available
Refurbishment Services
Available
Similar Listings
View AllNIKON
NSR-2205i12D
Steppers & ScannersVintage: 1997Condition: Refurbished
Last VerifiedOver 60 days ago
NIKON
NSR-2205i12D
Steppers & ScannersVintage: 1997Condition: Refurbished
Last VerifiedOver 60 days ago
NIKON
NSR-2205i12D
CATEGORY
Steppers & Scanners
Last Verified: 3 days ago
Key Item Details
Condition:
Used
Operational Status:
Unknown
Product ID:
162944
Wafer Sizes:
8"/200mm
Vintage:
Unknown
Logistics Support
Available
Transaction Insured by Moov
Available
Refurbishment Services
Available
Description
i-line stepperConfiguration
Software: MSCV ver 2.42C OCSV ver 2.42 TOOL ver 2.51A OpenVMS VAX V6.1 Optics: Variable NA, max NA 0.63 Max field size: 22 x 22 SHRINC type 3 illuminator: conventional, 1/2 annular TTLFC2 focus check PPD Chip leveling Reticle: 6" reticle, 6" reticle case Fixed reticle microscope Reticle barcode reader Wafer handling: Notch wafers Ring-type wafer chuck Pre-alignment 2 (8", N) with 6-hammer Wafer loader type 3 Wafer carrier tables: left and right In-line ready (left side) Alignment: FIA LSA HP 5517C laser Facilities: NEMA box, 2 lines for CVCF Rack on right side Body-OP rack cable: 3M Chamber: Asahi S19 (1997) Chamber temperature: 23.0°COEM Model Description
"This i-line stepper from Nikon is one of our most popular lithography systems. Resolution ≦ 350 nm, exposure light source i-line (365 nm wavelength), reduction ratio 1:5, exposure field 22mm square to 17.9 (H) × 25.2 (V) mm (6-inch reticle), 20.0 × 20.4 mm (5-inch reticle), alignment accuracy (EGA, |M| + 3σ) ≦ 55 nm. The NIKON NSR 2205 i12D is a Steppers and Scanners system. The NSR 2205 i12D can be used with 8” wafer sizes.Documents
No documents