NIKON NSR-2205i12D
    Description
    European CE Safety mark certification
    Configuration
    i-Line Stepper Performance Specification: 1. Resolution: 0.35μm or less High resolution, positive resist film of 1.0μm thickness 2. Focus Calibration Repeatability: Within 100nm (3σ) 20 measurements 3. Lens Distortion (including magnification error): Within ± 40nm 37 points / chip 4. Magnification Control: Within ± 15nm 3 measurements of Initial, Heat (180min.) and Cool (240min.) 5. Maximum Exposure Area: Within 31.11mm dia. 22.0mm x 22.0mm to 17.96mm x 25.2mm (hor.) X (vert.) 6. Reticle Blind Setting Accuracy: + 0.4 to + 0.8mm (on reticle) 7. Exposure Power: 800 mW/cm2 or more Measured after a new lamp is installed 8. Integrated Exposure Stability (including integrated exposure matching): Within ± 1.0% (50 mJ/cm2 or more) Within ± 0.5% (at 100mJ/cm2) 9. Illumination Uniformity Within ± 1.0% Inside exposure area 5 measurements
    OEM Model Description
    "This i-line stepper from Nikon is one of our most popular lithography systems. Resolution ≦ 350 nm, exposure light source i-line (365 nm wavelength), reduction ratio 1:5, exposure field 22mm square to 17.9 (H) × 25.2 (V) mm (6-inch reticle), 20.0 × 20.4 mm (5-inch reticle), alignment accuracy (EGA, |M| + 3σ) ≦ 55 nm. The NIKON NSR 2205 i12D is a Steppers and Scanners system. The NSR 2205 i12D can be used with 8” wafer sizes.
    Documents

    No documents

    verified-listing-icon

    Verified

    CATEGORY
    Steppers & Scanners

    Last Verified: 4 days ago

    Key Item Details

    Condition:

    Used


    Operational Status:

    Unknown


    Product ID:

    148409


    Wafer Sizes:

    6"/150mm


    Vintage:

    2006


    Logistics Support
    Available
    Transaction Insured by Moov
    Available
    Refurbishment Services
    Available
    Similar Listings
    View All
    NIKON NSR-2205i12D

    NIKON

    NSR-2205i12D

    Steppers & Scanners
    Vintage: 1999Condition: Used
    Last Verified14 days ago

    NIKON

    NSR-2205i12D

    verified-listing-icon
    Verified
    CATEGORY
    Steppers & Scanners
    Last Verified: 4 days ago
    listing-photo-24c09587707f4ce4989a9fbc4a3c876f-https://media-moov-co.s3.us-west-1.amazonaws.com/user_media/listingPhoto/1289/24c09587707f4ce4989a9fbc4a3c876f/64a2b128169d4edc90695fd857350f66_0b2b824d5cba4da1800d58be549938b0_mw.jpeg
    listing-photo-24c09587707f4ce4989a9fbc4a3c876f-https://media-moov-co.s3.us-west-1.amazonaws.com/user_media/listingPhoto/1289/24c09587707f4ce4989a9fbc4a3c876f/91f94878721d4f2fa5c8b6ae30d5ccdc_b8e40ddebd8446dea93f10915d90d2a31201a_mw.jpeg
    listing-photo-24c09587707f4ce4989a9fbc4a3c876f-https://media-moov-co.s3.us-west-1.amazonaws.com/user_media/listingPhoto/1289/24c09587707f4ce4989a9fbc4a3c876f/7133e5fbe2e94758919d1b19c1765ad2_5a87be7f0ffe4265a8ca35d07d21cc7f1201a_mw.jpeg
    Key Item Details

    Condition:

    Used


    Operational Status:

    Unknown


    Product ID:

    148409


    Wafer Sizes:

    6"/150mm


    Vintage:

    2006


    Logistics Support
    Available
    Transaction Insured by Moov
    Available
    Refurbishment Services
    Available
    Description
    European CE Safety mark certification
    Configuration
    i-Line Stepper Performance Specification: 1. Resolution: 0.35μm or less High resolution, positive resist film of 1.0μm thickness 2. Focus Calibration Repeatability: Within 100nm (3σ) 20 measurements 3. Lens Distortion (including magnification error): Within ± 40nm 37 points / chip 4. Magnification Control: Within ± 15nm 3 measurements of Initial, Heat (180min.) and Cool (240min.) 5. Maximum Exposure Area: Within 31.11mm dia. 22.0mm x 22.0mm to 17.96mm x 25.2mm (hor.) X (vert.) 6. Reticle Blind Setting Accuracy: + 0.4 to + 0.8mm (on reticle) 7. Exposure Power: 800 mW/cm2 or more Measured after a new lamp is installed 8. Integrated Exposure Stability (including integrated exposure matching): Within ± 1.0% (50 mJ/cm2 or more) Within ± 0.5% (at 100mJ/cm2) 9. Illumination Uniformity Within ± 1.0% Inside exposure area 5 measurements
    OEM Model Description
    "This i-line stepper from Nikon is one of our most popular lithography systems. Resolution ≦ 350 nm, exposure light source i-line (365 nm wavelength), reduction ratio 1:5, exposure field 22mm square to 17.9 (H) × 25.2 (V) mm (6-inch reticle), 20.0 × 20.4 mm (5-inch reticle), alignment accuracy (EGA, |M| + 3σ) ≦ 55 nm. The NIKON NSR 2205 i12D is a Steppers and Scanners system. The NSR 2205 i12D can be used with 8” wafer sizes.
    Documents

    No documents

    Similar Listings
    View All
    NIKON NSR-2205i12D

    NIKON

    NSR-2205i12D

    Steppers & ScannersVintage: 1999Condition: UsedLast Verified:14 days ago