Skip to main content
Moov logo

Moov Icon
CANON FPA-3000i4
    Description
    Stepper
    Configuration
    Illuminator - Normal (63,65): Intensity 5,180 W/m²; uniformity 1.9% LI/UC ratio (LIRC): 1.001% LI accuracy, total: 0.22% Masking blade accuracy: Total 35 µm; theta 100 ppm; gray zone 25 µm Focus and tilt stability: Focus Z 3σ 0.034 µm; tilt X 1.7 ppm; tilt Y 2.7 ppm; all channels 3σ 0.056 µm Focus and tilt drive repeatability: Focus Z 3σ 0.09 µm; tilt X 3.69 ppm; tilt Y 2.11 ppm Piezo matching error (L, M, R): -0.181% Uneven focus, maximum of X, Y, V: Tilt ON 2.48 ppm; tilt OFF -2.9 ppm XY stage orthogonality: 0.03 ppm XY stage scaling: X -0.02 ppm; Y 0.07 ppm Stepping accuracy: XX 16.1 nm; YY 25.7 nm Stepping repeatability: X 21.2 nm; Y 24.9 nm Bar mirror bow (X, Y): 5 nm Low mag fine: X -0.097 µm; Y 0.005 µm Field rotation, chip rotation: 0.22 ppm Lens distortion, Normal (63,65): DX 0.026 µm; DY 0.028 µm
    OEM Model Description
    The Canon FPA-3000 i4 is a stepper used in the semiconductor industry. It has a reticle size of 6" square with a thickness of 0.25" and is made of quartz material1. It can handle wafer sizes of 4" through 8" that are SEMI Standard, JEIDA, Notch/Flat. The Canon FPA-3000 i4 has a projection magnification of 1/5 X and a numerical aperture of .45 - .63. The field size is 22x22 17x26 and the exposure light is Kr F (365nm). The estimated throughput of the Canon FPA-3000 i4 is 59 wafers per hour for an 8" wafer with 60 shots and 22 mm field size. For a 6" wafer, it can handle up to 83 wafers per hour with 32 shots and 22 mm field size. The Canon FPA-3000 i4 has an alignment accuracy of less than 0.06 μm (mean + 3 σ). The Canon FPA-3000 i4 has a resolution of 0.35 μm.
    Documents

    No documents

    verified-listing-icon

    Verified

    CATEGORY
    Steppers & Scanners

    Last Verified: Over 30 days ago

    Key Item Details

    Condition:

    Used


    Operational Status:

    Unknown


    Product ID:

    155482


    Wafer Sizes:

    Unknown


    Vintage:

    Unknown


    Logistics Support
    Available
    Transaction Insured by Moov
    Available
    Refurbishment Services
    Available
    Similar Listings
    View All
    CANON FPA-3000i4

    CANON

    FPA-3000i4

    Steppers & Scanners
    Vintage: 0Condition: Used
    Last Verified22 days ago

    CANON

    FPA-3000i4

    verified-listing-icon
    Verified
    CATEGORY
    Steppers & Scanners
    Last Verified: Over 30 days ago
    listing-photo-e8e60d7cd9074912b256f001a45e16d2-https://api-v2.moov.co/listingPhotos/395292/image/md.jpg
    listing-photo-e8e60d7cd9074912b256f001a45e16d2-https://api-v2.moov.co/listingPhotos/395293/image/md.jpg
    listing-photo-e8e60d7cd9074912b256f001a45e16d2-https://api-v2.moov.co/listingPhotos/395294/image/md.jpg
    Key Item Details

    Condition:

    Used


    Operational Status:

    Unknown


    Product ID:

    155482


    Wafer Sizes:

    Unknown


    Vintage:

    Unknown


    Logistics Support
    Available
    Transaction Insured by Moov
    Available
    Refurbishment Services
    Available
    Description
    Stepper
    Configuration
    Illuminator - Normal (63,65): Intensity 5,180 W/m²; uniformity 1.9% LI/UC ratio (LIRC): 1.001% LI accuracy, total: 0.22% Masking blade accuracy: Total 35 µm; theta 100 ppm; gray zone 25 µm Focus and tilt stability: Focus Z 3σ 0.034 µm; tilt X 1.7 ppm; tilt Y 2.7 ppm; all channels 3σ 0.056 µm Focus and tilt drive repeatability: Focus Z 3σ 0.09 µm; tilt X 3.69 ppm; tilt Y 2.11 ppm Piezo matching error (L, M, R): -0.181% Uneven focus, maximum of X, Y, V: Tilt ON 2.48 ppm; tilt OFF -2.9 ppm XY stage orthogonality: 0.03 ppm XY stage scaling: X -0.02 ppm; Y 0.07 ppm Stepping accuracy: XX 16.1 nm; YY 25.7 nm Stepping repeatability: X 21.2 nm; Y 24.9 nm Bar mirror bow (X, Y): 5 nm Low mag fine: X -0.097 µm; Y 0.005 µm Field rotation, chip rotation: 0.22 ppm Lens distortion, Normal (63,65): DX 0.026 µm; DY 0.028 µm
    OEM Model Description
    The Canon FPA-3000 i4 is a stepper used in the semiconductor industry. It has a reticle size of 6" square with a thickness of 0.25" and is made of quartz material1. It can handle wafer sizes of 4" through 8" that are SEMI Standard, JEIDA, Notch/Flat. The Canon FPA-3000 i4 has a projection magnification of 1/5 X and a numerical aperture of .45 - .63. The field size is 22x22 17x26 and the exposure light is Kr F (365nm). The estimated throughput of the Canon FPA-3000 i4 is 59 wafers per hour for an 8" wafer with 60 shots and 22 mm field size. For a 6" wafer, it can handle up to 83 wafers per hour with 32 shots and 22 mm field size. The Canon FPA-3000 i4 has an alignment accuracy of less than 0.06 μm (mean + 3 σ). The Canon FPA-3000 i4 has a resolution of 0.35 μm.
    Documents

    No documents

    Similar Listings
    View All
    CANON FPA-3000i4