Skip to main content
Moov logo

Moov Icon
CANON FPA-3000i4
    Description
    28M06
    Configuration
    No Configuration
    OEM Model Description
    The Canon FPA-3000 i4 is a stepper used in the semiconductor industry. It has a reticle size of 6" square with a thickness of 0.25" and is made of quartz material1. It can handle wafer sizes of 4" through 8" that are SEMI Standard, JEIDA, Notch/Flat. The Canon FPA-3000 i4 has a projection magnification of 1/5 X and a numerical aperture of .45 - .63. The field size is 22x22 17x26 and the exposure light is Kr F (365nm). The estimated throughput of the Canon FPA-3000 i4 is 59 wafers per hour for an 8" wafer with 60 shots and 22 mm field size. For a 6" wafer, it can handle up to 83 wafers per hour with 32 shots and 22 mm field size. The Canon FPA-3000 i4 has an alignment accuracy of less than 0.06 μm (mean + 3 σ). The Canon FPA-3000 i4 has a resolution of 0.35 μm.
    Documents

    No documents

    verified-listing-icon

    Verified

    CATEGORY
    Steppers & Scanners

    Last Verified: 22 days ago

    Key Item Details

    Condition:

    Used


    Operational Status:

    Unknown


    Product ID:

    149718


    Wafer Sizes:

    6"/150mm


    Vintage:

    Unknown


    Logistics Support
    Available
    Transaction Insured by Moov
    Available
    Refurbishment Services
    Available
    Similar Listings
    View All
    CANON FPA-3000i4

    CANON

    FPA-3000i4

    Steppers & Scanners
    Vintage: 0Condition: Used
    Last Verified22 days ago

    CANON

    FPA-3000i4

    verified-listing-icon
    Verified
    CATEGORY
    Steppers & Scanners
    Last Verified: 22 days ago
    listing-photo-471200bfcd404bb581bfbf1cb3aeeaf1-https://media-moov-co.s3.us-west-1.amazonaws.com/user_media/listingPhoto/90179/471200bfcd404bb581bfbf1cb3aeeaf1/d0667d2253134d04b4d6c891290c84b7_1000161_f.JPG
    listing-photo-471200bfcd404bb581bfbf1cb3aeeaf1-https://media-moov-co.s3.us-west-1.amazonaws.com/user_media/listingPhoto/90179/471200bfcd404bb581bfbf1cb3aeeaf1/fdd1471a3e9c412ca2206025cf5377a6_1000163_f.JPG
    listing-photo-471200bfcd404bb581bfbf1cb3aeeaf1-https://media-moov-co.s3.us-west-1.amazonaws.com/user_media/listingPhoto/90179/471200bfcd404bb581bfbf1cb3aeeaf1/d000a8fb600b4aa69dc1f66ede3399b4_1000166_f.JPG
    listing-photo-471200bfcd404bb581bfbf1cb3aeeaf1-https://media-moov-co.s3.us-west-1.amazonaws.com/user_media/listingPhoto/90179/471200bfcd404bb581bfbf1cb3aeeaf1/26cd3fecf2f34de2a37f6ffee3228264_1000168_f.JPG
    listing-photo-471200bfcd404bb581bfbf1cb3aeeaf1-https://media-moov-co.s3.us-west-1.amazonaws.com/user_media/listingPhoto/90179/471200bfcd404bb581bfbf1cb3aeeaf1/9327c464f451438a986ce33e80aaed8d_1000165_f.JPG
    listing-photo-471200bfcd404bb581bfbf1cb3aeeaf1-https://media-moov-co.s3.us-west-1.amazonaws.com/user_media/listingPhoto/90179/471200bfcd404bb581bfbf1cb3aeeaf1/b3b401731603436499ea9e8902aad283_1000160_f.JPG
    listing-photo-471200bfcd404bb581bfbf1cb3aeeaf1-https://media-moov-co.s3.us-west-1.amazonaws.com/user_media/listingPhoto/90179/471200bfcd404bb581bfbf1cb3aeeaf1/35c636333cfc46a09d540acac77f9137_1000167_f.JPG
    listing-photo-471200bfcd404bb581bfbf1cb3aeeaf1-https://media-moov-co.s3.us-west-1.amazonaws.com/user_media/listingPhoto/90179/471200bfcd404bb581bfbf1cb3aeeaf1/706662aafb064eb1872c48ceadfa4f72_1000164_f.JPG
    listing-photo-471200bfcd404bb581bfbf1cb3aeeaf1-https://media-moov-co.s3.us-west-1.amazonaws.com/user_media/listingPhoto/90179/471200bfcd404bb581bfbf1cb3aeeaf1/485631171e3d47a2885140db2c820385_1000162_f.JPG
    Key Item Details

    Condition:

    Used


    Operational Status:

    Unknown


    Product ID:

    149718


    Wafer Sizes:

    6"/150mm


    Vintage:

    Unknown


    Logistics Support
    Available
    Transaction Insured by Moov
    Available
    Refurbishment Services
    Available
    Description
    28M06
    Configuration
    No Configuration
    OEM Model Description
    The Canon FPA-3000 i4 is a stepper used in the semiconductor industry. It has a reticle size of 6" square with a thickness of 0.25" and is made of quartz material1. It can handle wafer sizes of 4" through 8" that are SEMI Standard, JEIDA, Notch/Flat. The Canon FPA-3000 i4 has a projection magnification of 1/5 X and a numerical aperture of .45 - .63. The field size is 22x22 17x26 and the exposure light is Kr F (365nm). The estimated throughput of the Canon FPA-3000 i4 is 59 wafers per hour for an 8" wafer with 60 shots and 22 mm field size. For a 6" wafer, it can handle up to 83 wafers per hour with 32 shots and 22 mm field size. The Canon FPA-3000 i4 has an alignment accuracy of less than 0.06 μm (mean + 3 σ). The Canon FPA-3000 i4 has a resolution of 0.35 μm.
    Documents

    No documents

    Similar Listings
    View All
    CANON FPA-3000i4

    CANON

    FPA-3000i4

    Steppers & ScannersVintage: 0Condition: UsedLast Verified:22 days ago