Skip to main content
Moov logo

Moov Icon
HITACHI S-4700 II
    Description
    Stage with TMP High-resolution electron microscope Installation utility requirements: Room temperature: 15 ~ 25 °C or 59 ~ 77 °F Relative humidity: 60% or less Power: Single phase AC 100, 110, 115, 200, 220, 240V ±10%, 50/60 Hz, 4 kVA (Continuous supply is required.) Grounding: First grade grounding (Grounding resistance of 100 ohms or less) × 1 Cooling water: 1.5 ~ 2.0 l/min., 50 ~ 100 kPa 10 ~ 20°C, variation within 0.5°C/10 min.
    Configuration
    Accessories: Chamber scope Upgraded Turbo Molecular Pump Joystick Stage Controller SPECIFICATION Secondary electron image resolution: 2.1 nm at 1 kV 1.5 nm at 15 kV Electron optics: Electron gun Cold field emission electron source Acc. voltage 0.5 ~ 30 kV (variable at 0.1 kV/step) Probe current 1 pA ~ 2 nA (depends on Acc. voltage) Magnification ×20 ×500,000 Objective aperture Heated movable aperture, 4-opening, selectable and alignable outside the vacuum Image display: Operation/display OS: Windows NT with Internal Computer for extracting files. Scan mode: Normal, Split/dual mag./line scan, position set, spot, AAF, SAA, oblique Frame memory: 640 × 480 pixels, 1,280 × 960 pixels, 2,560 × 1,920 pixels Image filing Image data base with various reference functions built-in Image file format BMP, TIFF, JPEG selectable Scan speed TV, slow (0.5 ~ 40 s/frame) for viewing Slow (40 ~ 320 s/frame) for recording Image processing Automatic image brightness & contrast, raster rotation, autofocus, auto-stigmation, averaging, frame integration, color display Auto data recording Film numbering, acc. voltage, micron bar with a scale, magnification, date, hours and working distance Electrical image shift ±15 microns (at W.D = 12 mm) Vacuum system System Automatic vacuum sequence with pneumatic valve controls Evacuation: Vacuum ~10–7 Pa (electron gun), ~10–4 Pa (specimen chamber) Pumps Fore pumps 140 l/min (168 l/min) Diffusion pump 570 l/s × 1 set, and Ion pumps × 3 sets Protection System protection against power, water and vacuum failures. Dimensions & weight: Column 82 × 88 × 165 (H) cm, 410 kg (for type II stage) Display 120 × 90 × 137(H) cm, 235 kg Ion pump power supply 37 × 60 × 60 (H) cm, 75 kg Power unit 39 × 70 × 47 (H) cm, 35 kg Optional accessories EDX system, TMP vacuum system, Closed water circulator, RS-232C comunication interface, network interface.
    OEM Model Description
    HITACHI S 4700 II is a SEM & TEM system. The S 4700 II has standard secondary electron detector (SE), a backscatter electron detector (BSD) and a Gatan MonoCL cathodoluminescence detector (CL). The BSD is sensitive to slight energy variations occurring when a high energy electron scatters off the nucleus of an atom. This sensitivity allows the BSD to map out variations in the densities of the sample. The CL measures photons released by the sample as it interacts with the electron beam and uses the information gathered from these photons to conduct elemental analysis.
    Documents

    No documents

    verified-listing-icon

    Verified

    CATEGORY
    SEM / FIB

    Last Verified: 2 days ago

    Key Item Details

    Condition:

    Used


    Operational Status:

    Unknown


    Product ID:

    146121


    Wafer Sizes:

    Unknown


    Vintage:

    Unknown


    Logistics Support
    Available
    Transaction Insured by Moov
    Available
    Refurbishment Services
    Available
    Similar Listings
    View All
    HITACHI S-4700 II

    HITACHI

    S-4700 II

    SEM / FIB
    Vintage: 0Condition: Used
    Last Verified2 days ago

    HITACHI

    S-4700 II

    verified-listing-icon
    Verified
    CATEGORY
    SEM / FIB
    Last Verified: 2 days ago
    listing-photo-3b5086e7ccc2469ea8c166540865951c-https://media-moov-co.s3.us-west-1.amazonaws.com/user_media/listingPhoto/91091/3b5086e7ccc2469ea8c166540865951c/5b597c8e0e414f3e8d13f9d923b9826f_bc1f9b2a49af4233beb5eb682b161ec3_mw.jpeg
    listing-photo-3b5086e7ccc2469ea8c166540865951c-https://media-moov-co.s3.us-west-1.amazonaws.com/user_media/listingPhoto/91091/3b5086e7ccc2469ea8c166540865951c/247713f53ca541139b6256d93f886f19_c34a4458620a49a282bb1987416039bc_mw.jpeg
    listing-photo-3b5086e7ccc2469ea8c166540865951c-https://media-moov-co.s3.us-west-1.amazonaws.com/user_media/listingPhoto/91091/3b5086e7ccc2469ea8c166540865951c/5ed7aada3388471a8ef38245c11c4c51_5d9f401035a6494e8156ba2c44717343_mw.jpeg
    listing-photo-3b5086e7ccc2469ea8c166540865951c-https://media-moov-co.s3.us-west-1.amazonaws.com/user_media/listingPhoto/91091/3b5086e7ccc2469ea8c166540865951c/90b71c36dd42440da229c3440e25958a_0f9c28f1b663481697a1d105ab9eee3f_mw.jpeg
    listing-photo-3b5086e7ccc2469ea8c166540865951c-https://media-moov-co.s3.us-west-1.amazonaws.com/user_media/listingPhoto/91091/3b5086e7ccc2469ea8c166540865951c/b710d11ca2b44947a932870df2ae9b4f_f3abbb7dedf143489394dd22e3d657a4_mw.jpeg
    listing-photo-3b5086e7ccc2469ea8c166540865951c-https://media-moov-co.s3.us-west-1.amazonaws.com/user_media/listingPhoto/91091/3b5086e7ccc2469ea8c166540865951c/d220a6d695ba449fb2b605ae193d47aa_9dacbbf8d5c3418991b902f77a1649d5_mw.jpeg
    listing-photo-3b5086e7ccc2469ea8c166540865951c-https://media-moov-co.s3.us-west-1.amazonaws.com/user_media/listingPhoto/91091/3b5086e7ccc2469ea8c166540865951c/fe93c8f711aa4776b52596896dbbf51a_9293338074fb45dd9175694cf03fc565_mw.jpeg
    Key Item Details

    Condition:

    Used


    Operational Status:

    Unknown


    Product ID:

    146121


    Wafer Sizes:

    Unknown


    Vintage:

    Unknown


    Logistics Support
    Available
    Transaction Insured by Moov
    Available
    Refurbishment Services
    Available
    Description
    Stage with TMP High-resolution electron microscope Installation utility requirements: Room temperature: 15 ~ 25 °C or 59 ~ 77 °F Relative humidity: 60% or less Power: Single phase AC 100, 110, 115, 200, 220, 240V ±10%, 50/60 Hz, 4 kVA (Continuous supply is required.) Grounding: First grade grounding (Grounding resistance of 100 ohms or less) × 1 Cooling water: 1.5 ~ 2.0 l/min., 50 ~ 100 kPa 10 ~ 20°C, variation within 0.5°C/10 min.
    Configuration
    Accessories: Chamber scope Upgraded Turbo Molecular Pump Joystick Stage Controller SPECIFICATION Secondary electron image resolution: 2.1 nm at 1 kV 1.5 nm at 15 kV Electron optics: Electron gun Cold field emission electron source Acc. voltage 0.5 ~ 30 kV (variable at 0.1 kV/step) Probe current 1 pA ~ 2 nA (depends on Acc. voltage) Magnification ×20 ×500,000 Objective aperture Heated movable aperture, 4-opening, selectable and alignable outside the vacuum Image display: Operation/display OS: Windows NT with Internal Computer for extracting files. Scan mode: Normal, Split/dual mag./line scan, position set, spot, AAF, SAA, oblique Frame memory: 640 × 480 pixels, 1,280 × 960 pixels, 2,560 × 1,920 pixels Image filing Image data base with various reference functions built-in Image file format BMP, TIFF, JPEG selectable Scan speed TV, slow (0.5 ~ 40 s/frame) for viewing Slow (40 ~ 320 s/frame) for recording Image processing Automatic image brightness & contrast, raster rotation, autofocus, auto-stigmation, averaging, frame integration, color display Auto data recording Film numbering, acc. voltage, micron bar with a scale, magnification, date, hours and working distance Electrical image shift ±15 microns (at W.D = 12 mm) Vacuum system System Automatic vacuum sequence with pneumatic valve controls Evacuation: Vacuum ~10–7 Pa (electron gun), ~10–4 Pa (specimen chamber) Pumps Fore pumps 140 l/min (168 l/min) Diffusion pump 570 l/s × 1 set, and Ion pumps × 3 sets Protection System protection against power, water and vacuum failures. Dimensions & weight: Column 82 × 88 × 165 (H) cm, 410 kg (for type II stage) Display 120 × 90 × 137(H) cm, 235 kg Ion pump power supply 37 × 60 × 60 (H) cm, 75 kg Power unit 39 × 70 × 47 (H) cm, 35 kg Optional accessories EDX system, TMP vacuum system, Closed water circulator, RS-232C comunication interface, network interface.
    OEM Model Description
    HITACHI S 4700 II is a SEM & TEM system. The S 4700 II has standard secondary electron detector (SE), a backscatter electron detector (BSD) and a Gatan MonoCL cathodoluminescence detector (CL). The BSD is sensitive to slight energy variations occurring when a high energy electron scatters off the nucleus of an atom. This sensitivity allows the BSD to map out variations in the densities of the sample. The CL measures photons released by the sample as it interacts with the electron beam and uses the information gathered from these photons to conduct elemental analysis.
    Documents

    No documents

    Similar Listings
    View All
    HITACHI S-4700 II

    HITACHI

    S-4700 II

    SEM / FIBVintage: 0Condition: UsedLast Verified:2 days ago
    HITACHI S-4700 II

    HITACHI

    S-4700 II

    SEM / FIBVintage: 0Condition: UsedLast Verified:Over 60 days ago
    HITACHI S-4700 II

    HITACHI

    S-4700 II

    SEM / FIBVintage: 0Condition: RefurbishedLast Verified:Over 60 days ago