Skip to main content
Moov logo

Moov Icon
TAMARACK SCIENTIFIC CO., INC. 412
    Description
    Excimer Laser Ablation Stepper
    Configuration
    Laser Source: Coherent LPX Pro 305, 248 nm KrF excimer laser Application: Thin metal ablation Resolution: Down to 5 µm Alignment Accuracy: 1 µm Optical System: Chrome-on-quartz photomask with a 2.5X reduction projection lens Patterning Area & Repetition Rate: Single-pulse patterning up to 450 mm² (or 350 mm² at 50 Hz, based on < 100 mJ/cm² fluence requirement) Beam Size: Up to 450 mm² Substrate / Chuck Capacity: Up to 320 mm × 380 mm Frame & Isolation: Solid granite block lapped to 1 µm flatness, steel frame, vibration isolation Stage: Tamarack Gen 4 air-bearing X-Y table with motorized Z leveling Debris Handling: Integrated debris cell with collection system Safety: Class 1 laser enclosure
    OEM Model Description
    None Provided
    Documents
    verified-listing-icon

    Verified

    CATEGORY
    Laser Marker

    Last Verified: 13 days ago

    Key Item Details

    Condition:

    Used


    Operational Status:

    Deinstalled / Crated


    Product ID:

    160235


    Wafer Sizes:

    12"/300mm


    Vintage:

    2004


    Logistics Support
    Available
    Transaction Insured by Moov
    Available
    Refurbishment Services
    Available
    Similar Listings
    View All
    TAMARACK SCIENTIFIC CO., INC. 412

    TAMARACK SCIENTIFIC CO., INC.

    412

    Laser Marker
    Vintage: 2004Condition: Used
    Last Verified13 days ago

    TAMARACK SCIENTIFIC CO., INC.

    412

    verified-listing-icon
    Verified
    CATEGORY
    Laser Marker
    Last Verified: 13 days ago
    listing-photo-43966251bb814d02982015d3d7744991-https://api-v2.moov.co/listingPhotos/401071/image/md.jpg
    listing-photo-43966251bb814d02982015d3d7744991-https://api-v2.moov.co/listingPhotos/401068/image/md.jpg
    listing-photo-43966251bb814d02982015d3d7744991-https://api-v2.moov.co/listingPhotos/401070/image/md.jpg
    listing-photo-43966251bb814d02982015d3d7744991-https://api-v2.moov.co/listingPhotos/401073/image/md.jpg
    Key Item Details

    Condition:

    Used


    Operational Status:

    Deinstalled / Crated


    Product ID:

    160235


    Wafer Sizes:

    12"/300mm


    Vintage:

    2004


    Logistics Support
    Available
    Transaction Insured by Moov
    Available
    Refurbishment Services
    Available
    Description
    Excimer Laser Ablation Stepper
    Configuration
    Laser Source: Coherent LPX Pro 305, 248 nm KrF excimer laser Application: Thin metal ablation Resolution: Down to 5 µm Alignment Accuracy: 1 µm Optical System: Chrome-on-quartz photomask with a 2.5X reduction projection lens Patterning Area & Repetition Rate: Single-pulse patterning up to 450 mm² (or 350 mm² at 50 Hz, based on < 100 mJ/cm² fluence requirement) Beam Size: Up to 450 mm² Substrate / Chuck Capacity: Up to 320 mm × 380 mm Frame & Isolation: Solid granite block lapped to 1 µm flatness, steel frame, vibration isolation Stage: Tamarack Gen 4 air-bearing X-Y table with motorized Z leveling Debris Handling: Integrated debris cell with collection system Safety: Class 1 laser enclosure
    OEM Model Description
    None Provided
    Documents
    Similar Listings
    View All
    TAMARACK SCIENTIFIC CO., INC. 412

    TAMARACK SCIENTIFIC CO., INC.

    412

    Laser MarkerVintage: 2004Condition: UsedLast Verified:13 days ago
    TAMARACK SCIENTIFIC CO., INC. 412

    TAMARACK SCIENTIFIC CO., INC.

    412

    Laser MarkerVintage: 0Condition: UsedLast Verified:Over 30 days ago