Description
SELA/Camtek MC-500 Die/Wafer Microcleaver System ***This unit was donated to a local university by Texas Instruments. It powers up and loads the software. It looks to be functional.*** Brief Description: Fully Automatic Cross Sectioning System for Die and Wafer Level Samples. Dedicated software enables automatic mapping and planning of a single target. Fully automatic and programmable process. Minimum operator involvement. Improved and enhanced SEM and FIB utilization. Input: Minimum 4.2 x 2.1, Accuracy: 0.5 micrometers, 1 sigma. Throughput: 15 minutes/sample. Software: Dedicated, based on Windows 95.Configuration
The Unit's Serial Number Tag Reads: Model Number: MC 500 Serial Number: 05-521 Power Requirements: 115 V, 50/60 Hz, 16 A Air Pressure: 7 atm (110 psi) min. Information from the Unit: Software Version: MC500 v2.9 Optics: Eye Pieces: Olympus WH10X-H/22 and WH10X/22 Ojbectives: LMPlan FI 100X/0.80, ∞/0 LMPlan FI 50X/0.50, ∞/0 UMPlan FI 10X/0.30, ∞/0 MPlan APO 2.5X/0.08, ∞/-OEM Model Description
None ProvidedDocuments
No documents
Verified
CATEGORY
Inspection Equipment
Last Verified: Over 60 days ago
Key Item Details
Condition:
Used
Operational Status:
Deinstalled / Uncrated
Product ID:
126958
Wafer Sizes:
Unknown
HDD / Software:
Yes
Vintage:
Unknown
Logistics Support
Available
Transaction Insured by Moov
Available
Refurbishment Services
Available
CAMTEK / SELA
MC500
CATEGORY
Inspection Equipment
Last Verified: Over 60 days ago
Key Item Details
Condition:
Used
Operational Status:
Deinstalled / Uncrated
Product ID:
126958
Wafer Sizes:
Unknown
HDD / Software:
Yes
Vintage:
Unknown
Logistics Support
Available
Transaction Insured by Moov
Available
Refurbishment Services
Available
Description
SELA/Camtek MC-500 Die/Wafer Microcleaver System ***This unit was donated to a local university by Texas Instruments. It powers up and loads the software. It looks to be functional.*** Brief Description: Fully Automatic Cross Sectioning System for Die and Wafer Level Samples. Dedicated software enables automatic mapping and planning of a single target. Fully automatic and programmable process. Minimum operator involvement. Improved and enhanced SEM and FIB utilization. Input: Minimum 4.2 x 2.1, Accuracy: 0.5 micrometers, 1 sigma. Throughput: 15 minutes/sample. Software: Dedicated, based on Windows 95.Configuration
The Unit's Serial Number Tag Reads: Model Number: MC 500 Serial Number: 05-521 Power Requirements: 115 V, 50/60 Hz, 16 A Air Pressure: 7 atm (110 psi) min. Information from the Unit: Software Version: MC500 v2.9 Optics: Eye Pieces: Olympus WH10X-H/22 and WH10X/22 Ojbectives: LMPlan FI 100X/0.80, ∞/0 LMPlan FI 50X/0.50, ∞/0 UMPlan FI 10X/0.30, ∞/0 MPlan APO 2.5X/0.08, ∞/-OEM Model Description
None ProvidedDocuments
No documents