Skip to main content
Moov logo

Moov Icon
THERMOTRON FM-16-CHM-5-5
    Description
    Refrigeration hours 99,000+ Refrigerant: R23/R404A Power requirement: 480V/24A three phase Other facilities requirements: water for humidity system. Drain. There's no air purge on this chamber. Cooling: Water cooled; 1" NPT connections are provided. This chamber requires a fair amount of water at room temp in order to run at full capacity. Interior dimensions: 23.5" wide, 36.5" deep, 32" high Compressors: Two Copeland 5hp, bolted construction. Chamber heat: 4.5kW Steam generator: 4.5kW Humidity sensor: wet wick Controller: Thermotron 4800 it achieved -25C from 20C in five minutes; a further seven minutes resulted in -50C. Nine minutes were required to reach -60C from -50C. The heater works; it draws 6A at 480V three-phase. The steam generator shows good continuity. The humidity sensor does not work and the humidity coil did not energize when we enabled humidity in the control. The humidity water fill does work. A tag by the data plate states a refrigerant conversion was performed in 1995 from R13/R502 to R23/R404A. At this time a refrigerant expansion tank was added at the top of the chamber. Apparently, the 4800 control is original to this unit; it has several option cards including GPIB. The chart recorder is a Truline by Honeywell; it seems to work but we did not have a paper to test it with. A Destaco latch was installed to remedy a door leak. No manual or shelves are included.
    Configuration
    No Configuration
    OEM Model Description
    None Provided
    Documents

    No documents

    THERMOTRON

    FM-16-CHM-5-5

    verified-listing-icon

    Verified

    CATEGORY

    Environmental Chambers
    Last Verified: Over 60 days ago
    Key Item Details

    Condition:

    Used


    Operational Status:

    Unknown


    Product ID:

    52017


    Wafer Sizes:

    Unknown


    Vintage:

    1981

    Have Additional Questions?
    Logistics Support
    Available
    Money Back Guarantee
    Available
    Transaction Insured by Moov
    Available
    Refurbishment Services
    Available
    Similar Listings
    View All
    THERMOTRON FM-16-CHM-5-5
    THERMOTRONFM-16-CHM-5-5Environmental Chambers
    Vintage: 1981Condition: Used
    Last VerifiedOver 60 days ago

    THERMOTRON

    FM-16-CHM-5-5

    verified-listing-icon

    Verified

    CATEGORY

    Environmental Chambers
    Last Verified: Over 60 days ago
    listing-photo-5ae5c270363e4d9c8a9220cf50dd1a9c-https://d2pkkbyngq3xpw.cloudfront.net/moov_media/3.0-assets/photo-coming-soon-small.png
    Key Item Details

    Condition:

    Used


    Operational Status:

    Unknown


    Product ID:

    52017


    Wafer Sizes:

    Unknown


    Vintage:

    1981


    Logistics Support
    Available
    Money Back Guarantee
    Available
    Transaction Insured by Moov
    Available
    Refurbishment Services
    Available
    Description
    Refrigeration hours 99,000+ Refrigerant: R23/R404A Power requirement: 480V/24A three phase Other facilities requirements: water for humidity system. Drain. There's no air purge on this chamber. Cooling: Water cooled; 1" NPT connections are provided. This chamber requires a fair amount of water at room temp in order to run at full capacity. Interior dimensions: 23.5" wide, 36.5" deep, 32" high Compressors: Two Copeland 5hp, bolted construction. Chamber heat: 4.5kW Steam generator: 4.5kW Humidity sensor: wet wick Controller: Thermotron 4800 it achieved -25C from 20C in five minutes; a further seven minutes resulted in -50C. Nine minutes were required to reach -60C from -50C. The heater works; it draws 6A at 480V three-phase. The steam generator shows good continuity. The humidity sensor does not work and the humidity coil did not energize when we enabled humidity in the control. The humidity water fill does work. A tag by the data plate states a refrigerant conversion was performed in 1995 from R13/R502 to R23/R404A. At this time a refrigerant expansion tank was added at the top of the chamber. Apparently, the 4800 control is original to this unit; it has several option cards including GPIB. The chart recorder is a Truline by Honeywell; it seems to work but we did not have a paper to test it with. A Destaco latch was installed to remedy a door leak. No manual or shelves are included.
    Configuration
    No Configuration
    OEM Model Description
    None Provided
    Documents

    No documents

    Similar Listings
    View All
    THERMOTRON FM-16-CHM-5-5
    THERMOTRON
    FM-16-CHM-5-5
    Environmental ChambersVintage: 1981Condition: UsedLast Verified: Over 60 days ago